Products

Specifications

 

 

Design &controls

The pressure parts & equipment are designed in accordance with the code requirements such as ASME Sec VIII Div 1or II and PED etc.

The Heater bundle is designed to install in hazardous area zone 1 & 2, Gas group IIC, temperature class (T1 to T6), with IP 66 protection in accordance with ATEX & IEC Ex Standards.

The Control Panel can be of Thyristor control or contactor bases depending upon the operational requirements.

The control panel is designed to install in hazardous area zone 1 & 2, Gas group IIC, temperature class T6, with IP 65 protection in accordance with ATEX  CCOE Standards.

All the Instruments selected are suitable for Hazardous area installation with suitable certifications.

Alternatively, If the Ratings are high, the system can also be divided into two parts with Heating System and instruments in one skid and control Panel suitable for safe area installation (mounted in the panel room with extended wirings).

Pressure Vessels can be code stamped (U or U2) or PED or DOSH Certified.

Raw Materials for Vessel and piping’s can be Carbon steel, Low-temperature carbon steels, SS, Duplex steel or alloys.

Marathon can design and supply fuel gas heater system suitable for hazardous area installation with an ambient temperature range of -40°C to 60 °C.